manufacturer of I/O-rich SBCs, operator interfaces, handheld instruments, and development tools for embedded control low cost single board computers, embedded controllers, and operator interfaces for scientific instruments & industrial control development tools for embedded control order our low cost I/O-rich embedded control products embedded controller manufacturer profile single board computers & embedded controllers development tools & starter kits for your embedded design operator interfaces with touchscreens and graphical user interface plug-in expansion modules for digital & analog I/O C language & Forth language integrated development tools, IDE single board and embedded computer accessories embedded controller enclosures, bezels, environmental gaskets

The EtherSmart Wildcard User Guide

Table of Contents

Introduction

Internet Protocol Support

Summary of EtherSmart Capabilities

Hardware

Connecting To the Wildcard Bus

Selecting the Wildcard Address

Terminology Overview

Browser Notes

The EtherSmart Software Driver Routines

EtherSmart Driver Data Structures

The Demo Program

EtherSmart Initialization, Configuration and Diagnostics

Initialization Functions

Configuring the XPort Device

Assigning an IP Address

Reporting Routines

Using "Ping" for Diagnostics

Initializing Multiple EtherSmart Wildcards

Code Downloads and Interactive Communications via Ethernet

Serial Tunneling

A Serial Tunneling Example

Serial Tunneling Buffer Management Functions

Serial Tunneling Data Transmission and Reception Functions

Serial Tunneling Connection Functions

Serial Tunneling Inter-Task Service Management Functions

Sending Email

Introduction to the Dynamic Webserver

Using the Dynamic Webserver

HTTP Buffer Management

HTTP Header Generation

HTTP Data Transfer Functions

Web Form Processing

An Example of a Dynamic Web Page with a Remote Image Reference

Serving Out a Stand-Alone Image

Implementing a "Remote Front Panel" Using the Webserver

Appendix A: Installing the Software

Generating the EtherSmart Kernel Extension Library

Creating Web Page and Image Resources with the Image Converter

Loading the Software onto the Controller

Using the EtherSmart Driver with C

Using the Driver Code with Forth

Appendix B: C Demo Program

Appendix C: C Remote Front Panel Demo Program

Appendix D: Forth Demo Program

Appendix E: Forth Remote Front Panel Demo Program

Appendix F: Browser Configuration

Using Opera Is Highly Recommended

Reconfiguring the Internet Explorer Browser

Firefox and Mozilla

Appendix G: Hardware Schematic (pdf)

<< Previous | Next>>

Sending Email

The EtherSmart Wildcard enables your application program to send emails to other computers on the network when significant events occur. The driver software implements SMTP (Simple Mail Transfer Protocol) to enable the EtherSmart to send outgoing email to a mail server on the LAN (Local Area Network).  Outgoing emails can be used by your instrument to send alerts or status updates.

The Ether_Send_Email function handles all of the details for you.  You pass to the function the gateway IP address on your LAN, and strings that specify the sender email address, recipient email address, and the email body including an optional subject line.  The EtherSmart driver software and the mail server running on the gateway computer cooperate to process the email. 

Note that the XPort can connect only to destinations on the local network. If you need to send an email to a destination that is not on the LAN, address the email to the gateway (router) computer’s IP address, and ask your system administrator to configure the gateway to "relay" (forward) the email to the desired destination.  Also, note that the EtherSmart Wildcard can send emails, but cannot receive them.  To send a message to the EtherSmart, use a serial tunneling connection or a forms-based web connection as described in other sections of this document.

A Demonstration Email Function

Listing 1‑7  illustrates the Email_Test function from the demo program.  This interactively callable function is invoked by simply typing the following command into the terminal window:

 

Email_Test(  )

As usual, there must be no space before the ( and at least one space before the ) character.  An examination of Listing 1‑7 reveals how easy it is to send an email. Note that the hostname, sender, recipient, and IP address must be edited and the demo program compiled and downloaded for this function to work on your local network. 

The four string definitions at the top of Listing 1‑7 specify the hostname, email sender, email recipient, and the email body, respectively.  Edit these to represent values that make sense on your LAN.  Note that the first line of the email_body_str is:

 

Subject: EtherSmart Email Test\r\n\

This is the optional subject line. As shown, the word Subject: should be the first word on the line. The Ether_Send_Email routine automatically prepends a To: line to the email body, emplacing the recipient name string that is passed as an input parameter.  You can include other "email header" items in the body of your email, such as:

 

Date:

Cc:

From:

Each of these lines should be terminated with a carriage return/linefeed (\r\n) which is the standard end of line sequence for the SMTP protocol.

Listing 17     Interactive Email Test Function.

// ********************* EMAIL  TEST ***************************

 

// NOTE: Edit these to specify valid host, sender, and recipient:

char* hostname_str = "xport.yourdomain.com";   // hostname string

char* sender_str = "niceguy@yourdomain.com";  // email sender string

char* recipient_str = "notso_niceguy@yourdomain.com";   // email recipient string

 

char* email_body_str =  // email_body string

"Subject: EtherSmart Email Test\r\n\

This is a test email from the EtherSmart Wildcard.\r\n\

Emails can of course have multiple lines...";

#define SMTP_PORT 25  // email Simple Mail Transfer Protocol destination port

 

_Q int Email_Test( void )

// smtp email test routine.

// Note: YOU MUST EDIT THIS FUNCTION’s HARD-CODED IP ADDRESS

// AND the hostname_str, sender_str, and recipient_str BEFORE CALLING!

// Otherwise, it will not work on your system.

// error= 0 on success, or error_no_response = 0x10, or smtp 3-digit error code

{  xaddr scratchbuf = Ether_Inbuf( E_MODULENUM );     // scratchpad xbuffer

   Ether_Send_Email(

      STRING_XADDR(email_body_str), strlen(email_body_str), // subject plus email

      STRING_XADDR(hostname_str), strlen(hostname_str),

      STRING_XADDR(sender_str), strlen(sender_str),

      STRING_XADDR(recipient_str), strlen(recipient_str),

      scratchbuf,       // scratchpad xbuffer

      10, 0, 1, 1,      // IMPORTANT: ENTER YOUR GATEWAY’S IP ADDRESS HERE!

      SMTP_PORT,        // port 25 = standard mailserver destination port

      10000,            // use a 10 second timeout (10,000 msec) for testing

      E_MODULENUM);     // specify module number (must match hardware jumpers)

   return((int) Ether_Await_Response(E_MODULENUM)); // error code is in lsword

}

 

 

The Ether_Test function in Listing 1‑7 simply sets up the input parameter list and calls Ether_Send_Email. See the "EtherSmart Driver Data Structures: Passing String Extended Addresses as Function Parameters" section above for a discussion of the STRING_XADDR macro that converts a 16-bit string address to a full 32-bit xaddress as required by Ether_Send_Email. The four lines of after the function invocation specify the string xaddress and count for the subject, host name, sender, and recipient, respectively. 

In this example the scratchbuf local variable is defined as an xaddress that is initialized to the recommended email scratchpad buffer Ether_Inbuf(E_MODULENUM). As discussed in earlier sections, it is illegal to nest operating system function calls inside a parameter list of another operating system function call.  The definition and passing of scratchbuf enables us to pass the Ether_Inbuf xaddress without violating this rule.  The specified ram scratchpad buffer holds SMTP strings going to and from the XPort.  The recommended minimum scratchpad buffer length is 128 bytes; it must be able to hold the sender, recipient, and hostname strings plus sixteen extra bytes.  The email body is not transferred to the scratchpad buffer, so you can define an email body that is significantly longer than the scratchpad buffer.

This example shows a static email body, but you can create the email body "on the fly" in your application program.  To dynamically build up the email string in the Ether_Outbuf buffer, use the Ether_Outbuf_CAT function to build the email body one line at a time.  If you put the email body in Ether_Outbuf, pass the buffer xaddress+2 as the string xaddress, and the contents of the buffer xaddress as the count.  This is because Ether_Outbuf is an LBuffer with the 16-bit count stored in the first two bytes, followed by the data in the remainder of the buffer.  Because the buffer is typically in paged (as opposed to common) memory, you must use the operating system FetchInt to extract the count from the buffer.  In the example above, using Ether_Outbuf instead of email_body_str would involve declaring the new variables:

 

uint ether_outbuf_lcount;

xaddr ether_outbuf_xaddr = Ether_Outbuf(E_MODULENUM);

After the email body is loaded into the Ether_Outbuf using Ether_Outbuf_Cat, the following assignment can be performed:

 

ether_outbuf_lcount = FetchInt( ether_outbuf_xaddr);

Finally, in Listing 1‑7, to use Ether_Outbuf for the email body you would replace the line:

 

STRING_XADDR(email_body_str), strlen(email_body_str),

with the line:

 

ether_outbuf_xaddr+2, ether_outbuf_lcount,

to specify the email body xaddress and count.

After the strings and scratchpad buffer in the parameter list in Listing 1‑7, the next four parameters specify the destination IP address to which the email is directed. Often this is the IP of the gateway computer on the LAN, as the gateway often runs the mail server.  Make sure to edit the demo code to specify a valid IP address on the LAN.

The next parameter is the destination TCP/IP port number. In almost all cases this will be port 25, the SMTP port as defined by the constant in the demo program. 

The next parameter in the Ether_Send_Email invocation is a timeout in units of milliseconds.  It is important not to make this too small, as there can be significant delays on a network.  The example shows a 10 second (10,000 millisecond) timeout, but the value required on your network may be different.

The final parameter passed to Ether_Send_Email is the modulenum.

When the application program invokes Ether_Send_Email, a message is dispatched via the ether_command mailbox to the Ethernet task.  Consequently, the Ethernet task opens a connection to the specified remote computer, sends the email, and closes the connection. If there is a failure code returned while the email "chat" is occurring, this 3-digit decimal error code is returned and the email transaction is halted. The connection is closed before this routine exits; only 1 email is deliverable per connect.  The Ethernet task then sends the result error code in the ether_response mailbox. This mailbox must be cleared by the application program using either the blocking function Ether_Await_Response, or the non-blocking function Ether_Check_Response. The main loop of your program’s application task should periodically call one of these two functions to manage the interactions with the EtherSmart task.  In the example in Listing 1‑7, the return statement calls Ether_Await_Response and returns the 16-bit error code.

Using the Image Converter to Manage Long Strings

If you need to create long static email body strings, use the "Image Converter" program that is part of your Mosaic development environment.  This program converts one or more files, each containing a single string (or other resource) into a named 32-bit base xaddress and count that can be used by your application program.  Simply place each string into a separate file with the file extension .str or .html.  The file name and extension (with the dot replaced by an underscore) will become the symbol name.  All files to be converted should be in a single directory.  Make sure you use C-compatible filenames that include only alphanumeric and _ (underscore) characters, and do not start with a numeral.  Invoke the Image Converter from your development environment.  In the Image Converter control panel, select the controller platform, and check the "Web files" box.  If you are programming in Forth, click the "Advanced" menu and select Forth as the programming language.  In the "Directory" area of the control panel, select the directory that contains the specified file(s).  Then click on "Convert Files Now". 

A pair of files named image_data.txt and image.headers.h will be created by the Image Converter.  The image_data.txt contains S-records and operating system commands that load the string image into flash memory on the controller.  Because flash memory is nonvolatile, you only need to download this file once to the controller; it need not be reloaded until you change the resources.  The image_headers.h file declares the 32-bit xaddress and count (size) constants to be used by your application program. 

For example, let’s say that you have created a rather lengthy email body and stored it in a file named mail_body.str where the .str file extension indicates that the file contains a string.  The image_headers.h file declares the following two macros with the appropriate numeric xaddress and count values:

 

#define MAIL_BODY_STR_XADDR 0x700360

#define MAIL_BODY_STR_SIZE 0x98E

You can then use these macros as parameters passed to the Ether_Send_Email function to specify the email body string.  The use of the Image Converter is further described in the next section and in Appendix A.


Loading Your Program

See Appendix A for a discussion of how to load the resources and the kernel extension library files onto the controller board before loading your custom application program.