QScreen C User GuideTable of ContentsPART 1 GETTING STARTED Introduction. How to Use This Manual Chapter 1: Getting to Know Your QScreen Controller PART 2 PROGRAMMING THE QSCREEN CONTROLLER Chapter 3: The IDE: Writing, Compiling, Downloading and Debugging Programs Chapter 4: Making Effective Use of Memory Chapter 5: Real Time Programming Chapter 6: Failure and Run-Time Error Recovery PART 3 COMMUNICATIONS, MEASUREMENT, AND CONTROL Chapter 7: Digital and Timer-Controlled I/O Chapter 8: Data Acquisition Using Analog to Digital Conversion Chapter 9: Serial Communications RS-232 and RS-485 Communications Serial Connectors and Configuration Options Enabling RS485 Communica-tions Multi-Drop Communications Using RS-485 Synchronous Serial Peripheral Interface (SPI) SPI Clock Signal Configuration Chapter 10: The Battery-Backed Real-Time Clock PART 4: PUTTING IT ALL TOGETHER Chapter 11: A Turnkeyed Application PART 5: REFERENCE DATA |
Chapter 9 Serial CommunicationsRS-232 and RS-485 CommunicationsThe Qscreen Controller has two serial communications ports: a primary serial port called Serial 1 that supports both RS232 and RS485 protocols, and a secondary serial port called Serial 2 that supports RS232. The Serial 1 port is implemented with the 68HC11's on-chip hardware UART (Universal Asynchronous Receiver/Transmitter). Serial 2 is implemented by a software UART in the controller’s QED-Forth Kernel that uses two of the processor’s PortA I/O pins to generate a serial communications channel. Table 9‑1 Serial Communications Channels
The primary channel’s UART translates the bit-by-bit data on the serial cable into bytes of data that can be interpreted by the QED-Forth Kernel or by your application program. It controls the serial-to-parallel and parallel-to-serial conversion and performs all of the timing functions necessary for asynchronous serial communications. The communications is asynchronous because no synchronizing clock signal is transmitted along with the data. Rather, the UART deduces the correct time to sample the incoming signal based on the start and stop bits in the signal itself. (The QScreen Controller also supports fast synchronous serial communications via the Serial Peripheral Interface described later in this Chapter.) The secondary channel is very useful for debugging application programs that communicate with other computers or I/O via the primary channel. Since both channels can operate simultaneously and independently, debugging can be performed while the application program is communicating via its primary channel. The dual communications channels also provide an easy way to link systems that communicate using different serial protocols. Serial ProtocolsThere are several protocols that govern the format of exchanged data, with the RS232 protocol used primarily by personal computers, and the RS485 protocol used in industrial control systems. The Serial 1 port can be configured for either RS232 or RS485 communications at up to 19200 baud. The Serial 2 port is dedicated to RS232 communications at up to 4800 baud. RS232RS232 is by far the most common protocol. It is supported by virtually all personal computers, and is the default protocol for both of the QScreen Controller’s serial ports. Its simplest implementation requires only three wires: one to transmit serial data, a second to receive serial data, and a third to provide a common ground reference. RS232 allows both communicating parties to transmit and receive data at the same time; this is referred to as full duplex communications. RS232’s greatest benefit is its universality; practically all personal computers can use this protocol to send and receive serial data. If your computer does not have an RS-232 serial port, low cost USB-to-RS-232 serial cables are available; contact Mosaic Industries for details. RS232 uses inverse logic; that is, a positive bit at the 68HC11 UART is inverted by the onboard RS232 driver chip and appears as a negative signal on the serial cable. The terminal’s serial receiver chip re-inverts the signal to its positive sense. The data bits are also transmitted in reverse order, with the least significant bit transmitted first, after a start bit. The specified signal levels of approximately +/- 9 Volts are derived from the QScreen Controller’s +5 Volt supply by a dual RS232 driver chip that has a built-in charge pump voltage multiplier. RS485RS485 is another protocol supported by the primary serial port on the QScreen Controller. It is a half duplex protocol, meaning that only one party at a time may transmit data. Unlike the standard RS232 protocol, RS485 allows many communicating parties to share the same 3-wire communications cable. Thus RS485 is the standard protocol of choice when multi-drop communications are required. Like RS232, the data bits are transmitted in reverse order, with the least significant bit transmitted first. The RS485 protocol uses differential data signals for improved noise immunity; thus RS485 can communicate over greater distances than RS232. An RS485 transceiver is present on the QScreen Controller, and its data direction is controlled by pin 5 of port D of the 68HC11. Serial Connectors and Configuration OptionsThe primary and secondary serial communications ports are accessible through the QScreen's 10 pin, dual row Serial Header (H5) which is typically not installed, the 24 pin, dual row Field Header (H3), and through the individual DB-9 Serial 1 and Serial 2 connectors. A serial communications cable is also supplied with QScreen Starter Kits. The pinout of the QScreen’s Serial Header (H5), QScreen’s Field Header (H3), and the Serial Connectors are shown in the following tables. There are surface mount resistor pads on the QScreen that will allow you to bring out the secondary serial port to the Field Header on pins 5-6 or 7-8 as shown with the parentheses in Table 11-3. Pads are also available to bring out the RS485 signals to the DB9 Serial 1 Connector. Please contact Mosaic Industries if you need these custom configurations. Although the RS232 protocol specifies functions for as many as 25 pins, each communications channel requires only three for simple serial interfaces: TxD1 (transmit data), RxD1 (receive data), and DGND (digital ground). The RS232 protocol specifies the use of two separate grounds, a signal ground and a protective (or “chassis”) ground. The QScreen Controller does not differentiate between these. To provide a convenient means of attaching two grounds to the serial cable, there are several pins (labeled GND) on the communications connector that are connected to the controller’s ground plane. Table 9‑2 QScreen Serial Header, H5
Table 9‑3 QScreen Field Header, H3
Table 9‑4 Serial 1 Connector Table 9‑5 Serial 2 Connector
Given the availability of ready-made communications cables, it is not necessary to study or understand the following descriptions of cable connections. These detailed signal descriptions and cable diagrams are presented to provide complete information for those who have special communications requirements and for those who wish to make their own application-specific communications cables. Most computers conform to IBM PC AT-compatible RS232 interfaces which use 9-pin D-Type connectors, consequently the QScreen Controller brings out its serial ports to two female 9-pin D-Type connectors. Table 9‑6 shows the connection diagram for a standard 9-pin serial cable. Table 9‑6 Serial Cable Connections.
We can gain insight into the operation of the RS232 protocol by examining the signal connections used for the primary serial port in Table 9‑6. The transmit and receive data signals carry the messages being communicated between the QScreen Controller and the PC or terminal. The QScreen Controller’s transmit data signal TxD1 (pin 2 on the 9-pin serial connector) is connected to the terminal’s receive data signal RxD (pin 2 on its 9-pin connector). Likewise, the terminal’s transmit signal TxD is connected to the QScreen Controller’s receive signal RxD1. Chassis and signal grounds are connected together to the digital ground (GND) signal. From the QScreen Controller’s point of view, these three signals (TxD, RxD, and ground) are the only connections required to perform serial communications. While these signals provide a data path, they do not provide hardware handshaking that allows the two communicating parties to let each other know when they are ready to send or receive data. The RS232 protocol provides for four handshaking signals called ready to send (RTS), clear to send (CTS), data set ready (DSR), and data terminal ready (DTR) to coordinate the transfer of information. The QScreen Controller, however, does not implement hardware handshaking. Rather, it relies on software handshaking via transmission of XON/XOFF characters to coordinate data transfer and ensure that information is not lost when one of the communicating parties is busy. Many terminals and PCs, however, do rely on hardware handshaking to determine when the other party (in this case the QScreen Controller) is ready to accept data. By connecting pairs of these handshaking signals together, the terminal or PC can be made to think that the QScreen Controller is always ready to send and receive data. Thus in Table 9‑6 , RTS1 is connected to CTS1, and DSR1 is connected to DTR1 and DCD1 onboard the QScreen Controller using zero ohm shorting resistors. These signals may alternatively be redirected to the digital inputs and outputs used by the second serial port if hardware handshaking is required. The secondary serial port is connected similarly except that the onboard connection of RTS to CTS, and DSR to DTR are permanent. Enabling RS485 CommunicationsIf your application requires RS485, use the primary serial port (serial1) for RS485 communications, and use the secondary serial port (Serial 2) to program and debug your application code using the RS232 protocol. The default serial routines used by the onboard kernel assume that full duplex communications are available, so you cannot use the RS485 protocol to program the controller. You can use it to communicate with other devices. A jumper, J3, configures the primary serial port for either RS232 or RS485 operation. For RS232 operation: Remove the jumper shunt from J3. In this case, cable connections may be made to Serial 1 on either the 10-pin Serial Communications Header or the Serial 1 Connector. For RS485 operation: Install the jumper shunt onto J3. In this case, cable connections must be made to Serial 1 at pins 5 and 6 of the 10-pin Serial Header or pins 7 and 8 on the 24-pin Field Header. The RS485 connections are not brought out to the Serial 1 Connector. Using the Serial PortsUsing the primary serial port is easy. In fact, you have been using it all along as you worked through the examples in this document. The standard C serial I/O routines such as printf(), scanf(), putchar(), and getchar() give you high level access to the serial ports. All high level routines call the following low level revectorable serial primitives to access the currently active serial port:
int AskKey(void) // returns a flag that is true if an input char is waiting char Key(void) // waits for and returns the next input char void Emit(char) // outputs the specified char to the serial port
Because all of the serial I/O routines on the QScreen Controller are revectorable, it is very easy to change the serial port in use without modifying any high level code. Let’s do a quick experiment to see how easy it is. We’ll use code from the GETSTART.C program. If you have already downloaded the program, you are ready to go. If your board is presently running a multitasking application, type WARM to stop the program now. If you have not yet compiled the GETSTART program and you want to do the exercises here, open GETSTART.C in your TextPad editor, click on the Make Tool, and after the compilation is done, enter Mosaic Terminal by clicking on the terminal icon and use the “Send File” menu item to send GETSTART.DLF to the QScreen Controller. Switching the Default Serial PortBefore running the program, let’s switch to the secondary serial port. The secondary serial port is implemented by a software UART that controls two pins on PortA. Pin 3 of PortA is the Serial2 input, and pin 4 of PortA is the Serial2 output. To switch to the secondary serial port running at 1200 baud, simply type from the terminal the following QED-Forth commands: DECIMAL 1200 BAUD2 USE.SERIAL2 You can operate the port at any baud rate up to 4800 baud; just specify the rate you want before the BAUD2 command. Now select the “Comm” item in the “Settings” menu of the Terminal program, and click on 1200 baud (or whatever baud rate you selected in the command above). Move the serial cable from the “Serial Port 1” connector to the “Serial Port 2” connector on the QScreen. Typing a carriage return at the terminal should now produce the familiar “ok” response via the Serial2 port. Now type: main and you’ll see the familiar starting message of the GETSTART.C program: Starting condition: The radius is 0; the circular area is 0. ok In fact, the program works the same as it did before, but now it is using the secondary serial port instead of the primary port -- and you didn’t even have to recompile the code! For those of you interested in the details, here’s how it works: The low-level serial driver routines named Key(), AskKey() and Emit() are revectorable routines that can be redirected to use either of the serial ports. By interactively executing the QED-Forth function USE.SERIAL2 before calling main, we revectored these serial primitives to use the Serial2 port. You can invoke the C version of this routine by calling
UseSerial2() anywhere within your C program’s source code file. Function prototypes for this function and other versatile serial I/O routines are defined in the COMM.H header file, and are described in detail in the Control-C Glossary. To return to using the primary serial port, simply type from the active terminal the QED-Forth command: USE.SERIAL1 which transfers control back to serial port 1 running at the prior established baud rate (typically 19200 baud). A hardware reset (pressing down on the reset switch) has the same effect. If you do this now, remember to move the QScreen Controller’s serial connector back to Serial Port 1, and to change the terminal’s baud rate back to 19200 baud using the “Comm” item under the terminal’s “Settings” menu. If you always want the QScreen Controller to start up using the secondary serial port as the default serial communications link, you can type at your terminal: 1200 SERIAL2.AT.STARTUP where 1200 is the baud rate that you choose; you can specify any standard baud rate up to 4800 baud. The complementary routine is:
SERIAL1.AT.STARTUP which makes the primary serial port the default startup serial link. We recommend that you keep the faster Serial1 port as the default serial link as you work through the exercises in this book. All of these functions that we are calling interactively via the operating system can also be called from C in your program source code; their C function prototypes are as follows:
void UseSerial1( void ); void UseSerial2( void ); void Baud2( int baud ); void Serial1AtStartup( void ); void Serial2AtStartup( int baud ); In summary, the code provided for implementing the second serial port is very flexible and can be used to support dual concurrent communications ports. Data translation between different machines can be performed with ease, and applications that communicate via the primary serial port can be debugged using the secondary channel. Timing Considerations and MultitaskingIn multitasking systems using both serial ports Serial1 and Serial2, the application code should include one of the commands
SERIAL_ACCESS = RELEASE_ALWAYS; SERIAL_ACCESS = RELEASE_NEVER; before building the tasks. This prevents contention that can occur if the default RELEASE_AFTER_LINE option is installed in the SERIAL_ACCESS user variable. The primary serial port, Serial1, is supported by the 68HC11's on-chip hardware UART, and does not require interrupts to work properly. On the other hand, the secondary serial port (Serial2) is implemented using hardware pins PA3 (input) and PA4 (output), and is controlled by the associated interrupts IC4/OC5 and OC4, respectively. The QScreen Controller’s kernel software contains a complete set of high level driver routines for the Serial2 port, and these functions are summarized in the Control-C Glossary. The maximum Serial2 communications rate is 4800 baud. Because the software UART is interrupt based, competing interrupts that prevent timely servicing of the Serial2 interrupts can cause communications errors on the secondary serial channel. For example, at 4800 baud (bits per second), each bit lasts about 200 microseconds (µs), and if communications are full duplex (e.g., if the QScreen Controller echoes each incoming character), then there is a serial interrupt every 100 µs or so. In the middle of a character, each interrupt service routine takes about 35 µs. At the end of a received character, the service routine takes about 45 µs. At the start of a transmitted character, the service routine takes about 65 µs. Thus, as a rough approximation, operating at 4800 baud full duplex requires about 40 to 50% of the 6811's CPU time (that is, an average of approximately 40 to 50 µs service time every 100 µs). If you are running Serial2 at 4800 baud, the rest of your application must be able to function properly using the remaining portion of the CPU time. Moreover, if Serial2 is running full duplex at 4800 baud, any other interrupt service routine that takes longer than 100 µs is likely to cause a problem. If an interrupt service routine takes longer than 200 µs, then an entire serial bit will be missed, causing a communications error. Also, several non-serial interrupts can stack up; if they have higher priority than the serial interrupts, they will be serviced before the Serial2 interrupt routine, and again a serial input or output bit may be lost. Routines that temporarily disable interrupts for significant periods of time can also interfere with the Serial2 port. The Control-C Glossary contains a list of functions that temporarily disable interrupts, and the glossary entries give further information regarding how long interrupts are disabled. In most cases the times are less than 25 µs which does not pose a problem. However, note that the functions that write to EEPROM disable interrupts for 20 msec. per programmed byte. Be sure to account for these effects when designing your application. We have built sophisticated instruments using the QScreen Controller that operate very reliably using multiple interrupts in addition to the software UART. If your application requires use of the secondary serial port as well as other interrupt routines, the key is to keep the interrupt service routines short and fast. You might also consider operating the secondary serial port at a lower baud rate to relax the timing constraints. Setting Baud RatesThe rate of data transmission is expressed in bits per second, or baud. The primary serial channel can operate at standard speeds up to 19200 baud and can be configured for either RS232 (the default) or RS485 operation. The Serial2 channel is always configured for RS232 communications, and can sustain baud rates up to 4800 baud. The routines
void Baud1AtStartup( int baud ); void Serial2AtStartup( int baud );
make it easy to establish a standard baud rate at which the board will communicate each time it starts up. Although the maximum standard baud rate of the primary serial port is 19200 baud, nonstandard baud rates of over 80 Kbaud can be attained by the 68HC11's on-chip UART and the onboard RS232 driver. The maximum sustainable baud rate on the secondary serial port is 4800 baud. Multi-Drop Communications Using RS-485Connecting computers together in multi-drop networks is common in factories and laboratories. In these distributed processing networks, a variety of machines and instruments work locally, but communicate and share data or resources with one another globally using a single serial link. You can use the QScreen’s RS485 link to create such a multi-drop serial network. In the most common multi-drop RS-485 protocol, one computer is designated as a “master” and the rest of the computers or devices on the serial bus are designated as “slaves”. At any given time, only the master and a single “active” slave communicate. The remaining “inactive” slaves may actively receive, or listen to, data on the communications line, but only one slave at a time can transmit a message. If more than one slave tried to drive the transmit line simultaneously, their serial drivers would fight with each other for control of the bus. To ensure that no two devices drive the network at the same time, it is necessary that each slave device be able to disable it’s own RS-485 data transmitter. Software Implementation of an RS485 NetworkBecause the requirements of every multi-drop application are so unique, it is difficult to specify or design a software protocol that meets everyone’s needs. This section describes the QED-Forth routines that control the RS485 transceiver, and presents some ideas that may prove useful in designing a multi-drop data exchange protocol. The QScreen Controller controls the RS485 transceiver with bit 5 of Port D of the processor. When this bit is high, the transceiver is in transmit mode. When it is low, the transceiver is in receive mode. QED-Forth includes three built-in routines to facilitate control of the RS485 transceiver. They are:
void InitRS485( void ); void RS485Receive( void ); void RS485Transmit( void );
InitRS485() configures Port D to ensure that bit 5 is an output. RS485Receive() clears bit PD5 to place the transceiver in receive mode, and RS485Transmit() sets bit PD5 to place the transceiver in transmit mode. To use a QScreen as a slave in a multi-drop network, simply define a word, (named Silence(void), for example) that when executed calls RS485Receive() to wait for any pending character transmission to complete, then disable the transmitter, and then execute a routine such as Key() to listen to the communications on the serial bus. The Silence() routine searches the incoming serial characters for a pre-determined keyword (for example, the ascii “name” of this particular slave). When the network master wants to talk to this particular slave, it outputs the slave’s ascii name onto the serial bus. When the keyword name is received by the Silence() routine running in the slave, the slave QScreen Controller executes RS485Transmit() to send an acknowledgment to the master (which should now be listening to the serial bus to accept the acknowledgment). The master and slave can then exchange data. The data exchange format may be a line of ascii text . The master and slave could even exchange ascii QED-Forth commands. When the exchange is complete, the slave can again execute the Silence() routine to disable its transmitter and begin listening for its name. Synchronous Serial Peripheral Interface (SPI)The Serial Peripheral Interface, SPI, is a fast synchronous serial interface. It provides a convenient means of connecting the QScreen Controller to a variety of peripheral devices, including analog to digital and digital to analog converters, real time clocks, and other computers which use high speed communication. The SPI can transfer data much more rapidly than an asynchronous serial link – its maximum rate is 2 Megabits/second. After configuring the SPI system to communicate on a properly connected network of devices, sending and receiving data is as simple as writing and reading a register. The QED-Forth kernel includes pre-coded drivers that configure and control the SPI for maximum speed data transfers. This chapter describes those drivers, and presents code that makes it easy to configure the SPI for different data transfer rates and formats. SPI Bus PinsHardware is interfaced to the SPI via three PORTD pins named SCK, MOSI, and MISO brought out to pins 7, 8, and 10 on the Wildcard Port Header (see Appendix B). The SCK (serial clock) pin is a configurable synchronous data clock output. This signal synchronizes the exchange of bytes between the QScreen and its peripherals. The byte-sized messages are transmitted and received via the MOSI (master out/slave in) and MISO (master in/slave out) pins. The /SS (active-low slave select) is typically used to enable data transfers by slave devices when it is active low. For the QScreen, /SS is not used for SPI communication because it is used to control the direction of the RS485 transceiver; you can use any digital I/O line as a /SS signal. A ground connection is also necessary to ensure that the communicating devices have a common voltage reference. When the QScreen controls the network, it is referred to as a “master”; otherwise, it is a “slave”. The distinction between master and slave is an important one. The device that initiates a data transfer is the master, and all other devices on the network are slaves. Only one active master may control the network at a time; however, the device that assumes the role of master may change according to an appropriate protocol. If you are using the QScreen as a slave device and require the /SS signal for your external SPI hardware, configure one of the Port A pins on the Field Header as an input pin. By polling the Port A pin or by setting up an interrupt service routine, you can configure the QScreen to ignore the SCK input when /SS is high and keep MISO in a high-impedance state so that it does not interfere with the SPI bus. When the /SS input goes low, the slave (or QScreen in this case) transfers data in response to the SCK clock input that is initiated by the master. If you are using the QScreen as a master device, each external SPI device will require a separate select line (/SS). You can implement the slave select lines by configuring Port A pins as outputs. Remember that the /SS is active low so to select a device you need to set the pin low; otherwise the pin should idle high. There are many possible configurations of master/slave networks. Regardless of the network, however, there are only four signals used: SCK provides a synchronized clock, MOSI and MISO signals are used for data transmission and reception, and /SS configures the QScreen as a master or slave device. In this section we will consider the most general and simple configurations. SPI Network ConnectionsConfigured as a master device, the QScreen transmits bytes via the “master out/slave in” pin, MOSI. It receives bytes sent by a slave device via the “master in/slave out” pin, MISO. Transmissions are always initiated by the master device, and consist of an exchange of bytes. As the master transmits a byte to an active slave (that is, a slave with its /SS input active low), the master receives a byte from the slave. It may be that only the byte sent from the master to the slave is meaningful; nevertheless, each device simultaneously transmits and receives one byte. The only difference between the master and slave devices is that the master initiates the transmission. Slave devices use the master in/slave out pin, MISO, for transmitting, and the master out/slave in pin, MOSI, for receiving data. The following wiring diagram illustrates how the MOSI, and MISO pins of a master and a slave would be connected to exchange data:
The status of a device as master or slave determines how the various pins must be configured. The arrows in the diagram point to pins configured as inputs, and originate from output pins. Thus, the master has only one input, MISO, which is the slave’s only output. Note that the master device outputs the clock synchronization signal SCK to the slave’s SCK which is configured as an input. Also, in the diagram, the master’s /SS (slave select) is configured as an output. By setting this output LOW, the slave’s input /SS is pulled LOW. The GROUND line serves as a common voltage reference for the master and slave. There are a variety of ways the MOSI, MISO, SCK and /SS pins on your QScreen Controller can be connected. The one you choose depends on the specific device, or devices you will be connecting to. In some circumstances a one-way data flow may suffice. For example, a QScreen Controller connected to a serial A/D converter might have these connections:
In this example, the QScreen Controller selects the serial A/D by outputting a LOW signal on /SS. Even though the MOSI pin is not connected to anything, the master initiates a transmission using a “dummy” byte. The SCK pin clocks the serial A/D’s CLK input which causes the A/D’s conversion result to be transferred to the master via the MISO line. The QScreen allows the details of the synchronous communications protocol to be customized for compatibility with a variety of peripherals. The next section describes the registers that configure and control the QScreen Controller’s SPI. Configuring the SPIThe SPI is configured and accessed via four registers:
Given a properly wired network and a properly configured SPCR control register, a master device may transmit a message by simply storing the byte to the SPDR data register. This automatically activates the SCK clock which synchronously transmits the data. As the master transmits its data, 8 bits of data are simultaneously received. The received data byte is accessed by reading SPDR data register. This ability to exchange messages means that the SPI is capable of full duplex communication. Once the data has been exchanged, a flag bit in the SPSR status register is set to indicate that the transfer is complete. If the programmer has enabled the local interrupt mask for the SPI, an interrupt is recognized at this point. Any required SPI output signals must be configured as outputs, either by calling InitSPI() or by setting the appropriate bits in the Port D data direction register DDRD. The InitSPI() function provides a convenient way to initialize the SPI as the master at a 2MHz baud rate. This function properly configures the directions of the SPI I/O pins, and configures the data transfer such that data is valid on the falling trailing edge of the clock, with the clock idling in the low state. This configuration works for many SPI devices, including the optional battery-backed real-time clock. Consult the data sheets for any peripheral devices that you are interfacing to the SPI and, if a different configuration is needed, follow the instructions below to set up the appropriate SPI data transfer protocol. The BufferToSPI() function implements fast data transfer from a specified buffer in the controller’s memory to an SPI device. This function cannot accept incoming data; consult its glossary entry for details. Multitasking applications with more than one SPI device should control access to the SPI bus using the resource variable SPI_RESOURCE and the access control functions GET() and RELEASE(). Consult their glossary entries for details. Initializing the SPI Control RegisterThe SPI control register, SPCR, contains 8 bits which must be initialized for proper control of the QScreen Controller’s SPI (M68HC11 Reference Manual, Section 8.6.2). These bits are:
The DWOM bit (port D wired-or mode) should always be set to 0. Setting DWOM to 1 takes away the processor’s ability to pull the Port D signals high unless there is a pull-up resistor on each bit of the port. Setting this bit to 1 without installing pull-up resisters corrupts the operation of the serial communications interface which uses bits 0 and 1 of Port D. Setting SPE (SPI enable) to 1 turns on the SPI system. This bit should be set only after all other SPI configuration is complete. SPIE is a local interrupt mask that allows an interrupt to be recognized when an SPI data transfer has completed, or if a write collision or mode fault is detected. Setting the MSTR bit initializes the QScreen as a master, and clearing the MSTR bit initializes it as a slave. If the /SS pin of the master is an input and if a low input level is detected, the processor sets the MODF bit in the SPI status register a “mode fault” condition. This detects the presence of more than one master on the SPI bus. The CPOL, CPHA, SR1 and SPR0 configure the SCK pin’s clock polarity, clock phase, and clock rate. These signals are described in detail below. SPI Clock Signal ConfigurationThe SCK pin’s synchronous clock signal has configurable phase, polarity and baud rate so that it can interface to a variety of synchronous serial devices. In general, all devices on a network should use the same phase, polarity, and baud rate clock signal. In some cases, however, a sophisticated network may have device groups on a network that use different clock configurations. Although the devices would share the same network, communications would only be understandable by members of the same group. The clock’s polarity is controlled by a bit named CPOL (clock polarity) and its phase is controlled by CPHA (clock phase). CPOL determines whether the clock idles in the low state (CPOL = 0) or the high state (CPOL = 1). If the clock idles in the low state, the leading edge of the clock is a rising edge. If the clock idles in the high state, the leading edge of the clock is a falling edge. The CPHA bit determines whether data is valid on the leading or trailing edge of the clock. Note that the data is changed by the transmitting device one half clock cycle before it is valid. The following table summarizes the combinations of CPHA and CPOL settings:
Many serial devices require a clock that idles in the low state (CPOL = 0), and expect valid data to be present on rising clock edges. Thus in this common configuration the transmitting device outputs the data when the clock goes low, and the receiving device samples the valid data when the clock goes high (CPHA = 0). In other words, data is valid on the “rising leading edge” of the clock. To interface devices that support synchronized serial interfaces, but are not configurable like the QScreen, determine the device’s requirements for clock phase and polarity and configure the QScreen’s CPHA and CPOL accordingly. It is important to note that when the CPHA bit is 0, the /SS line must be de-asserted and re-asserted between each successive data byte exchange (68HC11 Reference Manual, Section 8.3.2). If the CPHA bit is 1, the /SS line may be tied low between successive transfers. SPI Baud RateThe two lowest order bits in the SPCR control register, named SPR1 and SPR0, determine the data exchange frequency expressed in bits per second; this frequency is also known as the baud rate. This setting is only relevant for the master device, as it is the master’s clock which drives the transfer. SPR1 and SPR0 determine the baud rate according to the following table:
Summary of the SPCR Control RegisterThe SPIE bit in the SPCR (SPI control register) enables SPI interrupt handling. The SPE bit turns on the SPI system. The DWOM bit determines whether Port D needs pull-up resistors; it should be set to 0. The MSTR bit determines whether the device is a master or slave. The CPOL and CPHA bits configure the synchronous clock polarity and phase and specify when valid data is present on the MISO and MOSI data lines. Finally, for master devices, the SPR1 and SPR0 bits determine the baud rate at which data is exchanged. SPI Status Register FlagsThere are three flag bits implemented in the SPSR (SPI status register). They are:
Any of these conditions may generate an interrupt if the SPIE (SPI interrupt enable) bit in the SPCR control register is set. The SPIF is set when a data transfer is complete, and is cleared by a read of the SPSR status register, followed by a read or write to the SPDR data register. Thus, resetting the SPIF flag is very simple. After a data transfer is initiated by writing to the SPDR data register, the processor may poll the SPSR status register until the SPIF flag is set. Then reading the data that was received (by reading the SPDR) or initiating a new data transfer (by writing to the SPDR) automatically clears the SPIF flag. Alternatively, the if the SPI interrupts are enabled, the SPI interrupt handler determines what caused the interrupt by reading the SPSR register to see which of the three status bits is set. If SPIF is set, reading the received data or initiating a new data transfer automatically clears the SPIF bit. A write collision occurs when a byte is written to the SPI data register, SPDR, while data is being exchanged. The WCOL flag is set when a write collision occurs. The data transfer that is in process when the write collision occurs is completed. WCOL is cleared by a read to the SPSR followed by a read or write to the SPDR. A mode fault occurs when the SPI senses that a multimaster conflict (MC68HC11F1 Technical Data Manual, p.8-7) exists on the network as explained above in connection with the /SS input. When a mode fault is detected, the processor: 1. disables the SPI outputs by clearing the bits in the Port D data direction register (DDRD), 2. clears the MSTR bit in the SPCR to configure the SPI as a slave, 3. clears the SPE bit to disable the SPI, and 4. generates an interrupt if the SPIE bit in the SPCR is enabled These steps greatly reduce the chance that the communicating devices might be damaged by contention on the SPI bus. The MODF bit is cleared by a read of the SPSR followed by a write to the SPCR. SPI Data TransfersA data transfer is initiated by a master device when it stores a message byte into its SPDR register. If a slave device has already stored a byte into its SPDR register, that byte will be exchanged with the master’s byte. Once the bytes have been exchanged, the master may write a new byte to initiate another byte exchange. Although data byte transfers are easily executed once the network has been wired and configured properly, a carefully executed software protocol may be required to ensure data integrity.
SummaryThe flexibility and power of the 68HC11’s serial peripheral interface supports high speed communication between the 68HC11 and other synchronous serial devices. The interface can be used to support analog to digital and digital to analog converters, networks of many computers controlled by a single master, or networks of devices controlled by several coordinated masters. Pre-coded device drivers configure the SPI for a standard data format, and it is easy to customize a data format and baud rate for your application. With careful design, many peripherals can communicate via the SPI, and powerful multi-processor systems can be linked using this high speed bus. |